vRA | Spas Kaloferov's Blog

Zero2Hero: Constraint Tags & Placement (SKKB1056)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this video we are going to talk about deployment decisions are being made in VMware Cloud Assembly and how we can affect these with Constraint and Capability Tags. Youtube Final Step   Update Log: Youtube Topics covered: Deployment Placement Decisions Extensibility Placement Decisions Using Constraint Tags to affect Placement Read more about Zero2Hero: Constraint Tags & Placement (SKKB1056)[…]

Zero2Hero: ABX Actions – Part 2 (SKKB1053)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this video we are going to look how we can use Action-Based Extensibility (ABX) in in Cloud Assembly. Youtube Final Step   Update Log: Youtube Part 2: Using Extensibility Tags with ABX Actions Working with Action Functions Using REST within ABX Actions Calling ABX Actions via REST and pulling Read more about Zero2Hero: ABX Actions – Part 2 (SKKB1053)[…]

Using Blueprint Options in Cloud Assembly (SKKB1051)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this blog post we are going to look at how to use Blueprint Options in Cloud Assembly to extend ABX extensibility. Introduction Blueprint Options Final Step   Update Log: Introduction Subscriptions in Cloud Assembly let you subscribe an extensibility action to a particular Event Type so that the action Read more about Using Blueprint Options in Cloud Assembly (SKKB1051)[…]

Using Cloud Assembly Native Auto-Scale Functionality (SKKB1048)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this blog post we are going to look at how to use VMware Cloud Assembly auto-scale functionality when building AWS Native Blueprints Introduction Configuring Auto-Scale in your Blueprint Final Step   Update Log: Introduction Assembly offers integration with AWS Auto-Scale functionality. You can set it up from your Blueprint Read more about Using Cloud Assembly Native Auto-Scale Functionality (SKKB1048)[…]

Managing NSX Manager Global Certificates (SKKB1040)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this article, we will look how to create and use VMware NSX Manager Global Certificates. Lab Environment Introduction Use Case Solution Final Step   Update Log: Lab Environment The full lab logical design can be seen HERE. Introduction   In a previous post called Managing NSX Edge and Manager Read more about Managing NSX Manager Global Certificates (SKKB1040)[…]

Configuring the vRealize Automation Plug-in for ITSM (ServiceNow) v1.0.0 – Part 2 (SKKB1039)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this article we will take a look how to configure The vRealize Automation plugin for ServiceNow . The Plug-in enables ServiceNow users to deploy virtual machines and perform day 2 actions on CMDB resources using vRealize Automation catalog and governance capabilities. Lab Environment PART 1: Configuring a Management, Infrastructure Read more about Configuring the vRealize Automation Plug-in for ITSM (ServiceNow) v1.0.0 – Part 2 (SKKB1039)[…]

Configuring the vRealize Automation Plug-in for ITSM (ServiceNow) v1.0.0 – Part 1 (SKKB1038)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this article we will take a look how to configure The vRealize Automation plugin for ServiceNow . The Plug-in enables ServiceNow users to deploy virtual machines and perform day 2 actions on CMDB resources using vRealize Automation catalog and governance capabilities. Lab Environment PART 1: Configuring a Management, Infrastructure Read more about Configuring the vRealize Automation Plug-in for ITSM (ServiceNow) v1.0.0 – Part 1 (SKKB1038)[…]

Unable to login to vRO with error Invalid Username or Password (SKKB1037)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this post we will take a look at what can be the cause of not being able to login to vRO, especially in the embedded vRO in a distributed vRA deployment,  with [invalid username/password] error. Lab Environment Issue Cause Solution Final Step Update Log: Lab Environment The full lab Read more about Unable to login to vRO with error Invalid Username or Password (SKKB1037)[…]

vRA Blueprint Deployment Fails with Error “Couldn’t find Host networks Expected [1], Got [0]” with NSX Components (On-Demand Load Balancer) (SKKB1034)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this post we will take a look into what can be the cause of not being able to deploy an On-Demand Load balancer from a VMware vRealize Automation Blueprint. In more particular when the NSX Edge deployment fails with error similar to “Couldn’t find Host networks Expected [1], Got Read more about vRA Blueprint Deployment Fails with Error “Couldn’t find Host networks Expected [1], Got [0]” with NSX Components (On-Demand Load Balancer) (SKKB1034)[…]

Renaming a vRA Managed vSphere Cluster or vSphere Host (SKKB1026)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this blog article we will see how can we rename vRealize Automation (vRA) 7.0 managed vSphere Cluster or vSphere Host without causing errors in vRA. Steps outlined here are also tested for vRA 6.2.3 Lab Environment Introduction Renaming a vSphere Host Preparation Execution Test Renaming a vSphere Cluster Preparation Read more about Renaming a vRA Managed vSphere Cluster or vSphere Host (SKKB1026)[…]

How to set vIDM (SSO) LDAP Site-Affinity for vRA (SKKB1024)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this article we take a look into how can we set LDAP site affinity for VMware Identity Manager (vIDM) and VMware Identity Appliance (IDA) , especially when used as Identity Provider by vRealize Automation (vRA). We will look into native vIDM options that let us accomplish this as well Read more about How to set vIDM (SSO) LDAP Site-Affinity for vRA (SKKB1024)[…]

Geo-Location Based Traffic Management with F5 BIG-IP for VMware Products (PoC): Use Case 2 (SKKB1018)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this article we will take a look at another VMware vRealize Automation Center (vRA) use case.  The use case describes a traffic management (Goe-Locaiton) scenario in which the vRA instances are installed is installed using the distributed deployment method. Part 1: Geo-Location Based Traffic Management with F5 BIG-IP for Read more about Geo-Location Based Traffic Management with F5 BIG-IP for VMware Products (PoC): Use Case 2 (SKKB1018)[…]

Geo-Location Based Traffic Management with F5 BIG-IP for VMware Products (PoC): Use Case 1 (SKKB1018)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this article we will take a look at our first use case. The use case describes a traffic management (Goe-Locaiton) scenario for vRealize Automation Center (vRA) instances spread across datacenters. The vRA instances use minimal deployment method. Part 1: Geo-Location Based Traffic Management with F5 BIG-IP for vRA (PoC) Read more about Geo-Location Based Traffic Management with F5 BIG-IP for VMware Products (PoC): Use Case 1 (SKKB1018)[…]

Geo-Location Based Traffic Management with F5 BIG-IP for VMware Products (PoC): Infrastructure Setup (continued) (SKKB1018)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this article we will talk more about the infrastructure used for the PoC. We will configure additional software components to provide local DNS (LDNS) services and configure Cent SO virtual machines to serve as clients in our infrastructure. Part 1: Geo-Location Based Traffic Management with F5 BIG-IP for vRA Read more about Geo-Location Based Traffic Management with F5 BIG-IP for VMware Products (PoC): Infrastructure Setup (continued) (SKKB1018)[…]

Geo-Location Based Traffic Management with F5 BIG-IP for VMware Products (PoC): F5 BIG-IP GTM Configuration (SKKB1018)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this article we will focus on the F5 BIG-IP Global Traffic Manager (LTM) configuration. We will take a look at LTM Datacenters, Servers, Listeners , ZoneRunner and DNS delegation, LTM with GTM integration, GTM with GTM integration, Pools, Wide IP’s, Topology records, and Distributed Applications. Part 1: Geo-Location Based Read more about Geo-Location Based Traffic Management with F5 BIG-IP for VMware Products (PoC): F5 BIG-IP GTM Configuration (SKKB1018)[…]

Geo-Location Based Traffic Management with F5 BIG-IP for VMware Products (PoC): F5 BIG-IP LTM Configuration (SKKB1018)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this article we will focus on the F5 BIG-IP Local Traffic Manager (LTM) configuration. This article assumes you have already deployed the LTM devices as described previously. We will take a look at LTM Monitors, Nodes, Pools , Load balancing and Virtual Servers. Part 1: Geo-Location Based Traffic Management Read more about Geo-Location Based Traffic Management with F5 BIG-IP for VMware Products (PoC): F5 BIG-IP LTM Configuration (SKKB1018)[…]

Geo-Location Based Traffic Management with F5 BIG-IP for VMware Products (PoC): Infrastructure Setup (SKKB1018)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this article we will talk about the infrastructure used for the PoC. We will go through the software components used and the requirements this PoC introduces. We will configure VMware NSX Manger, review DNS entries, deploy F5 BIG-IP GTM and LTM devices, configure F5 BIG-IP with 3rd party certificates, Read more about Geo-Location Based Traffic Management with F5 BIG-IP for VMware Products (PoC): Infrastructure Setup (SKKB1018)[…]

Geo-Location Based Traffic Management with F5 BIG-IP for VMware Products (PoC) (SKKB1018)

It's only fair to share…FacebookTwitterLinkedinDiggPinterestTumblrPrintemail In this article we will go thought an overview of this PoC and introduce some use cases that we will dig deeper into later. VMware vRealize Automation Center (vRA) will be one of the products in this Proof of Concept (PoC) for which use case(s) for Load balancing and geo-location Read more about Geo-Location Based Traffic Management with F5 BIG-IP for VMware Products (PoC) (SKKB1018)[…]